82.5 - 160 kVA TECHNICAL SPECIFICATIONS

Prime Rating at rated RPM (as per ISO8528) kVA 82.5 100 125 160
kW 66 80 100 128
Genset Model KG4-82.5WS1 KG4-100WS1 KG4-125WS1 KG4-160WS11
Frequency Hz 50
Power Factor Lagging 0.8
Voltage V 415 (3Ø)
Governing Class (ISO 8528 Part-V) G3
Noise Level dBA < 75
Fuel Tank Capacity (Standard DG Set) Ltrs 200 230 230 400
Weight of Genset with Canopy (Approx.) Dry (Kg) 1800 2170 2200 2980
Wet (w/o Fuel) (Kg) 1860 2230 2260 3050
Overall Dimensions of Genset Length (mm) 3200 3200 3200 4200
Width (mm) 1350 1350 1350 1450
Height (mm) 1595 1796 1796 1900
Electrical Battery Starting Voltage Volts-DC 12

ENGINE

Engine Model 4R1190ETA 4G1 4K1080ETA 4G1 4K1080ETA 4G1 6K1080ETA 4G1
Rated Output (ISO 8528-1) kW 77.2 114.7 114.7 147.1
HP 105 156 156 200
No. of Cylinders Number 4 4 4 6
Cubic Capacity Ltrs 4.76 4.32 4.32 6.48
Bore × Stroke mm 110 × 125 105 × 125 105 × 125 105 × 125
Rated Speed RPM 1500
Aspiration NA / TC / TA TA
Lube Oil Change Period hrs 500
Lube Oil Sump Capacity (Max) Ltrs 10 14 14 25
Coolant Capacity (Engine + Radiator) Ltrs 15.1 17.7 17.7 28.9
AdBlue / EF Capacity Ltrs 25

ALTERNATOR

Insulation Class Class H
Alternator Efficiency @100% Load (0.8 PF) % 91.1 89.6 91.9 92.4
Max Voltage Dip at Full Load (0.8 PF Lag) < 20%
Max Time to Build-up Rated Voltage @ Rated RPM < 2 sec, provided engine reaches rated speed

Genset kVA 82 to 160 kVA Features

‘Prime power’ is designed for Unlimited hours, as compared to ‘Emergency stand-by’ designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. Kirloskar offers Prime power as a standard offer. Contact Kirloskar for stand-by ratings.

  • Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.
  • Higher engine capacity also enables the Genset to respond quickly & positively to sudden load additions.

Kirloskar Gensets offer a unique combination of CPCB norm compliance and enhanced fuel efficiency. Across the range, Kirloskar Gensets offer substantial savings in fuel cost.

  • Genset ratings are selected based on the present load and future expansion. Fuel efficiency of most Gensets is optimized at the full rating of the Genset.
  • In practice, Gensets rarely get loaded to full capacity. Power demand variations across day & night, weekdays & weekends, summer & winter lead to an average 50-70% loading on Gensets.
  • Considering this practical situation, Kirloskar has extended fuel efficiency optimization from 100%, right up to 50% of rated load.
  • In line with fuel efficiency Kirloskar Genset ensures the better DEF efficiency and accordingly optimized the DEF tank size.
  • Combination of best-in-class fuel efficiency & 02E provides a double advantage.
  • EGR is used to reduce NOx emitted by the engine. By recirculating exhaust gases into the engine’s cylinder, a percentage of the air is replaced with CO₂.
  • It is an effective strategy to control NOx (Nitrogen Oxides) Emissions from diesel engines.
  • Some part of exhaust gas is recirculated in the combustion chamber.
  • Once mixed, the concentration of the oxygen in the fresh air is reduced and the temperature of the fresh air is increased slightly.

Common rail diesel injection technology, popularly known as CRDI, provides a significant upgrade over traditional mechanical fuel injection systems. CRDi provides precise fuel control, multiple injections, enhanced performance, lower noise and reduced emissions. High pressure common rail system employed on Kirloskar CPCB IV+ Gensets maximizes fuel atomization, delivering a smooth and smoke free performance. Diesel filters with ‘A’ class filtration are used for CRDi Engines which enhances the filtration efficiency. Common rail fuel injection system will provide a new level of performance, efficiency, and reliability.

Kirloskar gensets are enabled with Kirloskar remote monitoring system which shares Real Time Genset information and location services. It can be accessed via mobile device or desktop. Kirloskar remote monitoring system also highlights any parameter which needs special attention. These critical indication alerts are sent to user mobile via text message, It also alerts nearest services dealer in case of any emergency break-down.

Superior uptime. Genset comes with advanced diagnostic capabilities, this coupled with Kirloskar remote monitoring system provides real time monitoring of performance, emission and service critical parameters this helps for early diagnosis to fix the issues before system breakdown.

Kirloskar Genset put the command in your hands. Micro-processor based Genset controllers display a host of genset parameters and put all controls at your fingertips.

Monitoring Features

  • Phase Voltages & Currents, Frequency, Genset kVA, kW, kWh, kVA, Power Factor
  • Lube oil Pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Battery charge condition, AMF feature

Diagnostic Features

  • Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over kW, Phase Seq., Phase missing, Mains Under voltage, Low fuel level
  • Low Lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency

Optional Features

  • Modbus Communication

Kirloskar Gensets have always been preferred for their robust design and reliability over long usage life.

Kirloskar range carries the confidence of well-established and proven engine platforms. For compliance to revised CPCB norms, Kirloskar has carefully selected those technologies which not only retain, but enhance Gensets durability and on-site serviceability.

Thus, Kirloskar Gensets offer you many years of trouble-free performance; backed by the assurance of prompt support. Peace-of-mind driven by product reliability and low cost of ownership.

  • Kirloskar Alternator is compact in design, rugged and best in class efficiency.
  • Advanced Digital AVR improves the Voltage regulation and Response time.

Kirloskar CPCB compliant Gensets are having compact footprint which results in space saving. CPCB compliant technology is upgraded by maintaining the compact footprint of Genset.